A majority of the water heaters Water Heater Repair Oklahoma City receives repair inquiries for are gas water heaters. These are certainly the top type. Listed below are several self diagnostic tips one can test if the gas water heater is just not heating water whatsoever.

How to Self Diagnose an Oklahoma City Gas Water Heater Repair

It may appear totally obvious, nevertheless examine to guarantee the gas to the water heater is switched on. Switch the gas control knob to PILOT to keep the burner from igniting if looking within. Take off the metal cover at the lower part of the water heater and take a look to verify if the burner together with the pilot light are ignited.Gas Water Heater Repair Oklahoma City

If the water heater’s pilot light has gone out, stick to the recommendations on the storage tank to relight it (we have the general techniques to accomplish this detailed below). There may be a chance that the gas inlet valve is actually shut partly or completely. If that is the situation, move the handle parallel to the line and ignite the pilot. If the pilot continue to not ignite, then the difficulty may well be with the thermocouple. A lot of more recent water heaters possess a glow plug or spark igniter as an alternative to a pilot. Take note of the owner’s handbook for a guide.

If the burner is not on, replace the cover and make certain the thermostat is establish in the region of 120 degrees F. If it is not, change it, switch on a hot water faucet near the water heater, and wait around a couple of minutes to verify that the water heater burner ignites. If it doesn’t ignite, keep the hot water running and attempt decreasing and then increasing the temperature setting on the dial until eventually the burner ignites.

If perhaps the burner ignites, replace the cover and switch the thermostat again to the ideal setting. If the burner does not ignite, allow us to look at the water heater. The heater’s thermostat could possibly be faulty. A thermostat switch really should be carried out by us.

Do you smell gas? If a odor very much like garlic is found, switch the gas valve control to the OFF status. Hang on and examine if the gas odor has dissipated prior to relighting the pilot. If it does not go away, promptly shut off the gas supply valve, air out the room as best as you possibly can and contact the gas utility company.

Pilot Light Doesn’t Stay Lit

Attempt to relight the water heater initially. In simple terms, move the water heater’s gas valve to the OFF placement and after that to the PILOT location. Push the pilot button down in an effort to light it, and then hang on until a status light indicates the dial may be switched from PILOT to ON.

In case the pilot light continues going out, it’s possible the orifices may just be unclean and blocked, that can make the flame too little to remain lit. Examine to be sure there is no noticeable dirt and debris clogging it.

In the event everything seems to be clean, the trouble may perhaps be with the thermocouple. This is the element that runs from the temperature control straight into the flame of a pilot light and allows the main burner fire up when the water temperature has moved too low. The pilot light may very well be impacted if the thermocouple is bad or doesn’t come into contact with the pilot flame. Many property owners could possibly feel at ease changing a thermocouple, but Gas Water Heater Repair Oklahoma City would rather you contact us to assist.

Lower gas pressure or a not working gas control valve might also trigger a pilot light to go out continuously. Contact us if you believe that this is the event.